MOCK UP VPS BASE/CATALYST MSDS
Print MSDS
MOCK UP VPS BASE/CATALYST Material Safety Data Sheet



 1. Identification of Substance/Preparation and Company/Undertaking
Product Name:
MOCK UP VPS BASE/CATALYST
Manufacturer: Bisco, Inc. 1100 W Irving Park Road, Schaumburg, IL 60193 USA
Telephone: 1-847-534-6000, during normal business hours
Emergency Telephone Number: CHEMTREC - 24-Hour Hazmat Emergency Communications Center
Domestic: 1-800-424-9300 Outside the U.S.: 1-703-527-3887, collect calls accepted
CE Administrator: Bisico France, B.P. 60, 'L-Opera'-13680 Lancon de Provence
Emergency Telephone: (33)490.42.92.92

 2. Composition/Information on Ingredients
Ingredient Concentration Range (%) CAS Number Symbol/Risk
Classification
OSHA PEL (mg/m3) ACGIH (mg/m3) LD50
(mg/kg,
rat/oral)
 BASE:
Polyvinylsiloxane
Polyvinylsiloxane crosslinker
Talc
Hydrated Alumina
CATALYST:
Polyvinylsiloxane
Talc
Hydrated Alumina
 
<50
<25
<25
<40

<60
<25
<40
 
68083-19-2
Proprietary
14807-96-6
21645-51-2

68083-19-2
14807-96-6
21645-51-2
 
N/A
N/A
Xi; R36/37/38
Xi; R36/37/38

N/A
Xi; R36/37/38
Xi; R36/37/38
 
N/D
N/D
2
15

N/D
2
15
 
N/D
N/D
2
10

N/D
2
10
 
16ml/kg
N/D
N/D
N/D

16ml/kg
N/D
N/D
 
 3. Hazards Identification
Irritant, irritates to eyes, respiratory system and skin. May cause sensitization by skin contact,

 4. First Aid Measures
Inhalation: This product is considered safe if used according to the directions.
Skin Contact: Wash with soap and water.
Eye Contact: Wash with water for at least 15 minutes.
Ingestion: This product is considered safe if used according to the directions.
 5. Firefighting Measures
Firefighting media: Dry chemical powder, foam or carbon dioxide.
Fire and explosion risks: Upon combustion, irritating gases may form.
 6. Accidental Release Measures
Personal Precautions: Prevent skin/eye contact, provide ventilation,
Environmental Precautions: Avoid ground water contamination,
Methods for Cleaning Up: Wipe with damp paper towels, Discard properly,
 7. Handling and Storage
this product is used exclusively for dental purposes by trained personnel;

 8. Exposure Controls/Personal Protection
Eye Protection: Safety glasses and surgical face mask;
Hand Protection: Use protective gloves;
Respiratory Protection:Avoid prolonged breathing of vapors of uncured material;
Skin Protection:Use Any necessary hygiene measures. Avoid unnecessary exposure.;
 9. Physical/Chemical Properties
Appearance Paste Vapor Pressure @ 20C/68F N/A
Color Blue Miscibility N/A
Odor None Vapor Density N/A
Solubility (H2O, fat) N/A pH N/A
Boiling Point/Range N/A Evaporation Rate N/A
Melting Point/Range N/A Viscosity N/A
Flash Point >75 C / 167 F Partition Coefficient N/A
Conductivity N/A Autoflammability N/A
Explosive Properties N/A Flammability N/A
Oxidizing Properties N/A Relative Density N/A
 
10. Stability and Reactivity
Stable. Avoid high temperatures;

11. Toxicological Information
Eye Contact:Mild eye irritation. Use according to directions.;
Skin Contact: Irritates the skin;
Sensitization: No adverse health reaction is expected. Use according to directions.;
Other: N/A,
12. Ecological Information
There is no specific information on the product. Use according to good working practices.

13. Disposal Considerations
Refer to any Community provisions relating to waste. In their absence, refer to National or Regional provisions relating to waste.

14. Transport Information
No special precautions.

15. Regulatory Information
Classification: Xi Irritant, R36 Irritating to eyes, R37 Irritating to respiratory system, R38 Irritating to skin.,
Safety: Refer to any applicable National laws,
16. Other Information
Revision Date: 9/12/2008 Replaces MSDS dated: NA
Revision Number: 1 Product: MOCK UP VPS BASE/CATALYST

 

This information is believed to be correct as of the date of this MSDS. The manufacturer makes no representation as to the completeness or accuracy of this information and supplies it on the condition that the person receiving it will make their own determination as to its suitability for their purposes prior to use. In no event will the manufacturer be responsible for damages of any nature whatsoever resulting from the use of or reliance upon the information contained herein.

NOTE: CHEMTREC provides an emergency telephone number in the event of an emergency for leak, fire, exposure or accident involving the hazardous material that is being shipped. All non-emergency inquiries should be directed to Bisco during normal working hours
 
 
  Join our online communities for exclusive promotions and the latest news: bisco dental bisco dental  