1. Select the desired type and shade of ÆLITE Composite
prior to isolating and preparing the tooth:
- LS Posterior: for
Class I, Class II and Class VI
- All-Purpose Body:
Universal Composite for Class I - Class VI
- Aesthetic Enamel:
Enamel Layer for Class I - Class VI
TIP: To aid in shade
selection, place a small amount of material on the tooth and cure.
The composite is easily removed with the use of an instrument since
it has not been bonded to the tooth.
2. Clean the preparation with a slurry of pumice and water (or a
slurry of pumice and disinfectant, such as CAVITY CLEANSER*).
Rinse and dry the preparation.
3. When using a total-etch bonding
technique, etch the preparation using an etchant, such as ETCH-37*
or UNI-ETCH®* according to manufacturer's instructions.
- Apply etchant with supplied
needle tip. Allow etchant to remain in place for 15 seconds.
- To completely remove all
traces of etchant, rinse thoroughly (at least 5 seconds) and gently
dry, leaving the surface moist for the wet bonding technique.
- For best results, do not
allow enamel or dentin to dry for an excessive period of time.
Immediately re-wet enamel and dentin with a wetting agent such
as AQUA-PREP* F prior to application of hydrophilic adhesive.
4. Apply an adhesive, such as
ONE-STEP, ONE-STEP PLUS, or ALL-BOND 2, according to the manufacturer's
instructions.
| APPLYING
ONE-STEP or ONE-STEP PLUS |
a. With the surface visibly
moist, apply a minimum of two generous coats of ONE-STEP (OS) or
ONE-STEP PLUS (OS+). (If UNIT-DOSE is used, see instructions on
pouch to activate vial.)
b. Using a gentle stream of air, thoroughly evaporate the solvent
from the OS or OS+. (NOTE: The surface should be shiny. If
not, apply more OS or OS+ and evaporate solvent again.)
c. Light cure for a minimum of 10 seconds at 500mW/cm².
a. With the surface visibly
moist, mix ALL-BOND 2 Primers A & B (1:1) and apply a minimum
of five generous coats.
b. Using a gentle stream of air, thoroughly evaporate the solvent
from the A & B. (NOTE: The surface should be shiny. If
not, apply more A & B and evaporate solvent.)
c. Apply one coat of D/E Resin and air thin.
d. Light cure for 20 seconds
at 500mW/cm².
5. Place a small increment of
ÆLITE Liner into the cavity preparation to line the
pulpal floor, axial walls and gingival floor. (NOTE: remove
excess from margins when aesthetics are a concern) Light cure for
40 seconds (@500mW/cm²).
6. Dispense desired amount of
ÆLITE composite onto a light-protected mixing pad.
(Tip: To prevent excessive material from extruding, turn handle
counterclockwise immediately after the desired amount is dispensed.)
If using Unit-Dose Tips, inject ÆLITE composite directly
into preparation. NOTE: The properties of composite naturally
lend itself to adhere (stick) to your instrument. To overcome this
tackiness, MODELING RESIN was developed to aid in the placement
and shaping of your composites. By lightly wetting your instrument
with MODELING RESIN, all of your direct composite restorations can
be easily placed and manipulated (sculpted).
7. Using the selected shades,
place 1-2mm increments of composite into cavity preparation. Light
cure each increment with a curing light, such as VIP* junior
(refer to curing chart for curing time intervals.) Keep the
light tip as close to the composite as possible without contact.
Continue to build incrementally until cavity preparation is filled
to the cavosurface margin and the restoration takes on the desired
shape. Each surface of the final increment should be light-cured
for the amount of time specified in the curing chart.
| Curing Chart
(at 500mW/cm²): |
|
|
|
|
|
| Product |
For each 1-2mm
increment, light cure for: |
For the final
increment, light cure each surface for: |
| AESTHETIC ENAMEL |
20 seconds |
30 seconds |
| ALL-PURPOSE
BODY |
20 seconds |
30 seconds |
|
Opaque
shades > 1 mm |
30 seconds |
|
| LS POSTERIOR
|
|
|
|
A1, A2, A3, B1, C2, D3 |
20 seconds |
40 seconds |
| LS POSTERIOR
|
|
|
|
A3.5, C4 |
40 seconds |
40 seconds |
8. Check the occlusion and finish.
To minimize or eliminate polishing, apply BisCover* LV. Surface
sealants such as FORTIFY* or FORTIFY PLUS may also be used
according to manufacturer's instructions. The use of any of these
products will improve marginal integrity and reduce wear and staining.
a. Apply acid etchant, such
as UNI-ETCH, to the cured composite and adjacent tooth structure
for 15 seconds.
b. Rinse and dry.
c. If using a bottle of BisCover LV, dispense into a mixing
well. Dip the brush into the BisCover LV. Wipe excess from
the brush onto the side of mixing well. The brush does not need
to be saturated, just wet enough to apply one thin coat. If using
the BisCover LV syringe, apply directly using the syringe
and an applicator tip. (NOTE: This is a low viscosity material and
as such care must be taken to control the amount of material dispensed
from the syringe. It is also recommended that the tip be removed
from the syringe and the cap replaced immediately upon completion
of application.)
d. Apply one thin coat of BisCover LV in one direction with
a smooth stroke. Do not agitate the brush during application. It
is very important that one allows 15 seconds dwelling time
for evaporation of solvent after application. Do not air thin
as this will disperse the material unevenly causing ripples on the
surface.
CAUTION: Upon curing, BisCover LV may produce a brief
exothermic reaction which is minimized by applying in a thin layer.
Do not cure on soft tissue.
e. BisCover LV uses the
following curing lights and curing times to initiate polymerization.
It is important to properly cure BisCover LV since insufficient
curing will leave an air-inhibited layer on the surface.
i. LED Lights: Using
an LED curing light with a minimum output
of 500mW/cm², light cure for 30 seconds at close range
(0-2mm).
ii. Halogen Lights:
Using a halogen curing unit, such as VIP junior, with a minimum
output of 500mW/cm², light cure for 30 seconds at close
range (0-2mm).
NOTE: If the light intensity
is lower than 500mW/cm² and/or curing occurs at a distance
(>2 mm), light cure for greater than 30 seconds.
iii. PAC (Plasma Arc) Lights:
Using a PAC light, light cure for 10 seconds at close range
(0-2mm).
f. If a second coat is desired,
repeat steps c-e.
STORAGE: Store at room
temperature (22°C/72°F). See individual component labels
for specific expiration dates.
PRECAUTIONS: Unpolymerized
resins may cause skin sensitization in susceptible persons. In case
of contact, wash skin with soap and water.
WARRANTY: BISCO, Inc.
recognizes its responsibility to replace products if proven to be
defective. BISCO, Inc. does not accept liability for any damages
or loss, either direct or consequential, stemming from the use of
or inability to use the products as described. Before using, it
is the responsibility of the user to determine the suitability of
the product for its intended use. The user assumes all risk and
liability in connection therewith.
CAUTION: U.S. Federal
law restricts this device to sale by or on the order of a dental
professional.
* ALL-BOND 2, ONE-STEP, and
UNI-ETCH are registered trademarks of BISCO, INC.
ÆLITE, CAVITY CLEANSER, ETCH-37, AQUA-PREP, VIP, BisCover
and FORTIFY are trademarks of BISCO, INC.
U.S. Patent: 6,709,271
BISCO, Inc.
1100 W. Irving Park Rd.
Schaumburg, IL 60193
U.S.A.
847-534-6000
1-800-BIS-DENT
www.bisco.com
CE ADMINISTRATOR
Bisico France -
Mr. Fred Picavet
L'Opera- BP. 60
13680 Lançon De Provence
France
Phone: 33-490-42-9292
Fax: 33-490-42-9261
IN-131R1
Rev. 10/06
|