1. Select an appropriate shade of ÆLITE LS prior to
tooth desiccation.
2.
Isolate tooth and prepare the cavity in a conservative manner.
Clean the entire surface with a slurry of pumice and a disinfectant
such as CAVITY CLEANSER™* or water.
3.
Etch using an etchant, such as ETCH-37™* or UNI-ETCH®*, according
to manufacturer's instructions.
4.
Apply an adhesive, such
as ALL-BOND 2, ONE-STEP or ONE-STEP PLUS according to the manufacturer's
instructions.
5.
Dispense desired amount of appropriate shade of ÆLITE LS composite
onto a light-protected mixing pad by turning syringe handle clockwise.
To prevent excess material escaping from syringe, turn handle counterclockwise
immediately after the desired amount is dispensed. If using Unit-Dose
Tip, inject composite directly into preparation.
6.
Using the previously selected shade, place 1-2 mm increments of
composite into cavity preparation. Refer to the following table
or the "Calculating Curing Time" section and light-cure each increment.
Continue to build incrementally until cavity preparation is filled
to the cavosurface margin. The final increment should be light-cured
for 40 seconds.
500m
mW/cm2 |
A2,
B1, C2 |
A3.5,
C4, D3 |
| Light-cure
15 sec. |
Light-cure
40 sec. |
7.
Check the occlusion and begin finishing procedures. After finishing
and polishing have been completed, rinse the tooth and restoration
with a copious amount of water to remove all debris.
8.
Etch the surface of the restoration and approximately 1-2
mm beyond the tooth/restoration margin, for 15-20 seconds.
9.
Rinse with a copious amount of water and thoroughly air-dry
the tooth and restoration.
10.
Place a new needle brush-tip on the FORTIFY PLUS syringe and
push the plunger until the needle brush-tip is soaked with
the surface sealant. Apply a thin layer to previously etched
surfaces using a scrubbing motion. Air-thin by blowing a gentle
stream of air over this layer to assure an even distribution.
11.
Light-cure the surface sealant for 10 seconds. Verify occlusion.
WHAT
IS EOP?
Energy for Optimization of Polymerization
[EOP] is the minimum amount of energy required to achieve
clinically acceptable polymerization of a 2mm thick layer
of composite, assuming the tip of the curing light is 1-2mm
away from the composite surface. EOP differs with the shade
of the composite.
CALCULATING CURING TIME: Energy delivered to the surface
of the composite depends on power density of the light, spectral
output of the light [useful energy], exposure time and the
distance between the light probe and the composite surface.
Assume the EOP on a composite syringe label is 10 Joules [10J].
You must first determine the output, or power density [expressed
as PD], of your halogen or PAC light. Use a radiometer to
determine this value. For example, if you set your light output
(PD) for 500mW/cm2, then the calculation is as follows:
1.
Conversion: 10J [from the composite label] is equivalent to
10,000 mJoules.
2.
Curing time required = EOP/PD = 10,000/500 = 20 seconds
HOW
SUPPLIED:
ÆLITE
LS SYRINGE KIT
H-72010K
4 Syringes ÆLITE LS (4g ea.) Shades: A2, A3.5, B1, C2, 1 Bottle
ONE-STEP PLUS (6ml), 1 Syringe FORTIFY PLUS (1.5g), Accessories,
Instructions/MSDS
ÆLITE
LS UNIT-DOSE KIT
H-72020K
4 Shades, 15 Unit-Dose Tips ea. ÆLITE LS (0.25g ea.) Shades: A2,
A3.5, B1, C2, 1 Bottle ONE-STEP PLUS (6ml), 1 Syringe FORTIFY PLUS
(1.5g), Accessories, Instructions/MSDS
SYRINGE
REFILLS (1 Syringe (4g), Instructions/MSDS)
| A2 |
H-721A2P |
C2 |
H-721C2P |
| A3.5 |
H-721A35P |
C4 |
H-721C4P |
| B1 |
H-721B1P |
D3 |
H-721D3P |
UNIT-DOSE
REFILLS (15 Unit-Dose Tips (0.25g ea.), Instructions/MSDS)
| A2 |
H-722A2P |
C2 |
H-722C2P |
| A3.5 |
H-722A35P
|
C4 |
H-722C4P |
| B1 |
H-722B1P |
D3 |
H-722D3P |
STORAGE: Store at room temperature (22°C/72°F). Refer
to individual component labels for specific expiration dates.
PRECAUTIONS:
Unpolymerized resins may cause skin sensitization in susceptible
persons. In case of contact with the skin, wash thoroughly
with soap and water.
WARRANTY:
Bisco, Inc. recognizes its responsibility to replace products
if proven to be defective. Bisco, Inc. does not accept liability
for any damages or loss, either direct or consequential, stemming
from the use of or inability to use the products as described.
Before using, it is the responsibility of the user to determine
the suitability of the product for its intended use. The user
assumes all risk and liability in connection therewith.
CAUTION:
U.S. Federal law restricts this device to sale by or on the order
of a dental professional.
* ÆLITE, FORTIFY, CAVITY
CLEANSER, and ETCH-37 are trademarks of Bisco, Inc.
ALL-BOND, ONE-STEP, and UNI-ETCH are registered trademarks of Bisco,
Inc.
VITA is a registered
trademark of VITA ZAHNFABRIK H. Rauter GmblH & Co. KG Germany.
Patent Pending
Bisco, Inc.
1100 W. Irving Park Rd.
Schaumburg, IL 60193
1-(800)-BIS-DENT
847-534-6000
CE ADMINISTRATOR
Bisico France -
Mr. Fred Picavet
L'Opera- BP. 60
13680 Lancon De Provence
France
Phone: 33-490-42-9292
Fax: 33-490-42-9261
IN-093R1
Rev. 07/03
|