1. Select ÆLITE LS
Packable shades prior to isolating and preparing the tooth.
2. Clean the preparation with a slurry of pumice and water or a
disinfectant, such as CAVITY CLEANSER*. Rinse and dry the
preparation.
3. Etch the preparation using
an etchant, such as ETCH-37* ,
UNI-ETCH®*
or TYRIAN SPE, according to the manufacturer's instructions.
4. Apply an adhesive, such as ALL-BOND ,
ONE-STEP
or ONE-STEP PLUS ,
according to the manufacturer's instructions.
5. For preparations with highly
irregular internal surfaces, place a flowable composite, such as
ÆLITEFLO* LV, as the initial increment to maximize the
adaptation of ÆLITE LS Packable DENTIN to the preparation.
6. Dispense desired amount of
ÆLITE LS Packable composite onto a light-protected
mixing pad by turning the syringe handle clockwise.
NOTE: To prevent excess material from extruding, turn the syringe
handle counterclockwise immediately after the desired amount is
dispensed.
7. Place 1-2 mm increments of
composite into cavity preparation and build the restoration incrementally.
Light-cure each increment for 20 seconds at 500mW/cm2.
Use the pre-selected DENTIN shade initially and then the
ENAMEL shade. Fill to the cavosurface margin. The final increment
should be light-cured for 30 seconds.
8. Check the occlusion and begin
finishing procedures. Apply a surface sealant such as FORTIFY*
or FORTIFY PLUS, according to the manufacturer's instructions, OR
if using BisCover*
Liquid Polish, finish and apply BisCover according to the manufacturer's
instructions. These products will improve marginal integrity and
reduce wear and staining.
| MANUFACTURER'S
INSTRUCTIONS |
a. Apply etchant using an EZ-DOSE*
TIP, a disposable syringe tip, or disposable brush tip. Allow etchant
to remain in place for 15 seconds. Etching time should begin at
the end of application.
b. Rinse thoroughly (at least
5 seconds) to completely remove etchant.
| ONE-STEP
or ONE-STEP PLUS |
a. With the surface visibly
moist, apply a minimum of two generous coats of ONE-STEP (OS) or
ONE-STEP PLUS (OS+). (To activate UNIT-DOSE VIAL, see instructions
on pouch.)
b. Using a gentle stream of
air, thoroughly evaporate the solvent from the OS or OS+.
NOTE: The surface should be shiny. If not, apply more OS
or OS+ and evaporate solvent again.
c. Light-cure for a minimum
of 10 seconds at 500mW/cm2.
a. With the surface visibly
moist, mix ALL-BOND 2 Primers A & B and apply a minimum of five
generous coats.
b. Using a gentle stream of air, thoroughly evaporate the solvent
from the A & B.
NOTE: The surface should be shiny. If not, apply more A &
B and evaporate solvent.
c. Apply one coat of D/E Resin and air thin.
d. Light-cure for 20 seconds at 500mW/cm2.
APPLYING BISCOVER:
a. To the cured composite and
adjacent tooth structure, apply etchant (UNI-ETCH)for 15 seconds.
b. Rinse and dry.
c. Apply one thin coat of BisCover.
d. Using a conventional halogen light, light-cure for 30 seconds
at 500mW/cm2 (7.5J/cm2).
WHAT IS EOP?
Energy for Optimization
of Polymerization [EOP] is the minimum amount
of energy required to achieve clinically acceptable polymerization
of a 2mm thick layer of composite, assuming the tip of the curing
light is 1-2mm away from the composite surface. EOP differs with
the shade of the composite.
CALCULATING CURING TIME:
Energy delivered to the surface of the composite depends on power
density of the light, spectral output of the light [useful energy],
exposure time and the distance between the light probe and the composite
surface. Assume the EOP on a composite syringe label is 10 Joules
[10J]. You must first determine the output, or power density [expressed
as PD], of your halogen or PAC light. Use a radiometer to determine
this value. For example, if you set your light output (PD) for 500mW/cm2,
then the calculation is as follows:
| |
1. Conversion:
10J [from the composite label] is equivalent to 10,000 mJoules. |
| |
2.
Curing time required = |
EOP |
= |
10,000
|
= |
20
seconds |
|
| |
|
PD
|
|
500 |
|
|
|
|
STORAGE: Store
at room temperature (22°C/72°F). Refer to individual component
labels for specific expiration dates.
PRECAUTIONS: Unpolymerized
resins may cause skin sensitization in susceptible persons. In case
of contact with the skin, wash thoroughly with soap and water.
WARRANTY: Bisco, Inc.
recognizes its responsibility to replace products if proven defective.
Bisco, Inc. does not accept liability for any damages or loss, either
direct or consequential, stemming from the use of or inability to
use the products as described. Before using, it is the responsibility
of the user to determine the suitability of the product for its
intended use. The user assumes all risk and liability in connection
therewith.
CAUTION: U.S. Federal
law restricts this device to sale by or on the order of a dental
professional.
HOW SUPPLIED:
ÆLITE LS Packable SYRINGE
KIT
H-87210K
2 Syringes DENTIN (4g ea.) Shades: A2, A3, 2 Syringes ENAMEL (4g
ea.) Shades: NEUTRAL, YELLOW GRAY, 1 Syringe BisCover (1ml), 1 Bottle
ONE-STEP PLUS (2ml), 1 Syringe UNI-ETCH w/ BAC (5g), Accessories,
Instructions/MSDS
ÆLITE LS Packable
SYRINGE REFILLS (1 Syringe (4g), Instructions/MSDS)
| DENTIN SHADES |
ENAMEL SHADES |
| A1 |
H-872A1P |
NEUTRAL |
H-872ENP |
| A2 |
H-872A2P |
YELLOW
GRAY |
H-872EYGP |
| A3 |
H-872A3P |
|
|
REFILLS
BisCover 2 Syringe Package
G-93260P
2 Syringes BisCover Liquid Polish (1ml ea.), Accessories, Instructions/MSDS
G-9321P
1 Bottle BisCover Liquid Polish (5ml), Instructions/MSDS
U-2001P
1 Bottle ONE-STEP PLUS (6ml), Instructions/MSDS
E-5502EBM
4 Syringes UNI-ETCH w/ BAC (5g ea.), 60 Light Blue Disposable Syringe
Tips, Instructions/MSDS
E-5627EB
1 Economy Bottle UNI-ETCH w/ BAC (18g), Instructions/MSDS
* ALL-BOND, ONE-STEP and
UNI-ETCH are registered trademarks of BISCO, INC.
ÆLITE, CAVITY CLEANSER,
ETCH-37, TYRIAN, ÆLITEFLO, FORTIFY, BISCOVER
and EZ-DOSE are trademarks of BISCO, INC.
VITA is a registered
trademark of VITA ZAHNFABRIK H. Rauter GmblH & Co. KG Germany.
See section for Manufacturing
Instructions.
Bisco, Inc.
1100 W. Irving Park Rd.
Schaumburg, IL 60193
U.S.A.
847-534-6000
1-(800)-BIS-DENT
www.bisco.com
CE ADMINISTRATOR
Bisico France -
Mr. Fred Picavet
L'Opera- BP. 60
13680 Lancon De Provence
France
Phone: 33-490-42-9292
Fax: 33-490-42-9261
IN-136