PRECAUTIONS:
Hydrofluoric acid is a very powerful and aggressive chemical.
It is a severe eye and tissue irritant. If accidentally splashed
into the eye, flush with copious amounts of water for 15 minutes
and seek immediate medical attention. Hydrofluoric acid also releases
a vapor that irritates respiratory passageways. Chronic inhalation
of fumes is dangerous and can cause damage. Extreme care must be
taken to protect the patient, operator and assistant. These individuals
must wear protective eyewear. The operator and assistant must wear
protective gloves. Rubber dam isolation must be used for intraoral
porcelain repair.
If PORCELAIN
ETCHANT comes in contact with other tissues: rinse affected
area immediately with copious amounts of water for several minutes.
Injury may result if etchant is allowed to remain on the skin or
mucosa for any length of time.
BISCO's 4%
PORCELAIN ETCHANT has been buffered, gelled and packaged to
minimize problems, provided that it is used in accordance with these
instructions. Do not use this product until you have thoroughly
read and understood these instructions.
ETCHING ALL-CERAMIC
RESTORATIONS PRIOR TO CEMENTATION
1. Protective
eyewear and gloves must be worn by operator and assistant.
2. If the lab hasn't already etched the restoration, apply
PORCELAIN ETCHANT to the dried internal surface for 5-6 minutes.
Care must be taken to avoid having the etchant contact glazed porcelain
surfaces since these surfaces will lose their gloss.
NOTE: Not all ceramic systems are etchable. Contact your lab for manufacturer's
instructions.
3. Rinse with copious amounts of water to remove etchant and air
dry. The etched surface may appear dull and frosty.
4. Apply one to two thin coats of silane, such as BIS-SILANE or PORCELAIN
PRIMER, with a brush to the etched internal surface of the restoration
and allow to dwell for 30 seconds. Dry with air syringe.
5. Use an adhesive
system, such as ALL-BOND 2®*, ALL-BOND 3 or ONE-STEP®*/ONE-STEP PLUS, according to the manufacturer's instructions.
6. Continue with cementation according to the manufacturer's instructions.
REPAIR OF
ALL-CERAMIC RESTORATIONS AND SURFACES WITH EXPOSED METAL
1. Protective
eyewear must be worn by patient, operator and assistant. Protective
gloves must be worn by operator and assistant.
2. Freshen and roughen the porcelain repair site by using a diamond
bur. (Remove any old composite remaining from previous repairs.)
3. Isolate the
area to be etched with a rubber dam. BISCO's BARRIER GEL should
be placed where etching is not desired.
4. PRECAUTION: Confirm that syringe tip is adequately placed
and tightly attached. Test that etchant is flowing freely from the
syringe tip by expressing a small amount onto a mixing pad. If there
is resistance to flow, DO NOT proceed. Replace tip and test flow
again before using on patient.
5. Apply
PORCELAIN ETCHANT to the dried repair site for 5-6 minutes.
To evacuate hydrofluoric acid vapors, hold evacuator tip adjacent
to repair site. Monitor the etch site throughout the entire procedure.
NOTE:
Not all ceramic systems are etchable. Contact your lab for manufacturer's
instructions.
6. Rinse with
copious amounts of water to remove etchant and air dry. The etched
surface may appear dull and frosty.
7. Apply one
to two thin coats of silane, such as BIS-SILANE or PORCELAIN PRIMER, with a brush to the etched surface of the restoration and allow
to dwell for 30 seconds. Dry with air syringe.
8. Use an adhesive
system, such as ALL-BOND 2, ALL-BOND 3 or ONE-STEP/ONE-STEP PLUS, according
to the manufacturer's instructions.
9. Continue
with the porcelain repair applying BISCO's OPAQUER on exposed metal
and the appropriate composite, such as ÆLITE* All-Purpose Body, according to the composite manufacturer's instructions.
STORAGE:
Store at room temperature (22°C/72°F). Refer to individual
component labels for specific expiration dates.
PRECAUTIONS:
PORCELAIN ETCHANT is a severe eye and tissue irritant. If accidentally
splashed into the eye, flush with a copious amount of water for
15 minutes and seek immediate medical attention.
If PORCELAIN ETCHANT comes in contact with other
tissues: rinse affected area immediately with a copious amount of
water for several minutes. Injury may result if etchant is allowed
to remain on the skin or mucosa for any length of time.
WARRANTY:
BISCO, Inc. recognizes its responsibility to replace products if
proven defective. BISCO, Inc. does not accept liability for any
damages or loss, either direct or consequential, stemming from the
use of or inability to use the products as described. Before using,
it is the responsibility of the user to determine the suitability
of the product for its intended use. The user assumes all risk and
liability in connection therewith.
CAUTION:
U.S. Federal law restricts this device to sale by or on the
order of a dental professional.
* ALL-BOND 2
and ONE-STEP are registered trademarks of BISCO, Inc.
BIS-SILANE, ALL-BOND 3 and ÆLITE are trademarks of BISCO, Inc.
BISCO, Inc.
1100 W. Irving Park Rd.
Schaumburg, IL 60193
U.S.A.
847-534-6000
1-800-BIS-DENT
www.bisco.com
CE ADMINISTRATOR
Bisico France -
Mr. Fred Picavet
L'Opera- BP. 60
13680 Lançon De Provence
France
Phone: 33-490-42-9292
IN-018R3