PIT and FISSURE SEALANT is a light cured, filled, radiopaque,
white sealant designed to seal the pits and fissures of
caries susceptible teeth. |
DIRECTIONS FOR USE |
1. Clean
the surfaces of the teeth to be sealed with prophy paste
or pumice. Rinse thoroughly. Isolate the teeth to be sealed
with a rubber dam or cotton rolls.
2. Place a small amount of ETCH-37™ (37% H3PO4) on the
surface of the tooth using the disposable angled syringe
tip and manipulate the etchant into the pits and fissures.
3. Allow the etchant to remain on the tooth for 15 seconds.
Thoroughly rinse the etchant with a generous water spray.
Remove pooled water with an oil-free stream of compressed
air. Isolation of the etched surface is paramount to the
success of the procedure.
4. SHAKE SEALANT BOTTLE WELL BEFORE DISPENSING. The disposable
black dispenser tips can be placed directly on the sealant
bottle to dispense SEALANT, or use the supplied brushes.
Place a thin layer of sealant on the etched areas of the
tooth.
5. Cure the sealant for at least 20 seconds on each surface.
For thicker or larger applications, longer exposures are
desirable.
6. Check the applied sealant both visually and with an
explorer. If any part of the sealant can be dislodged
by the explorer, contamination of the etched surface has
occurred. Remove the dislodged sealant and repeat the
entire procedure beginning with step 1 above.
7. Check occlusion after the sealant has been cured and
adjust for any premature contact.
STORAGE: Store at room temperature (22°C/72°F).
See individual component labels for specific expiration
dates.
CAUTIONS: ETCH-37 contains phosphoric acid. Avoid
splashing into the eyes. If etchants come in contact with
the eyes, flush with copious amounts of water and seek
medical attention. Unpolymerized resins may cause skin
sensitization in susceptible persons. In case of contact
with the skin, wash thoroughly with soap and water.
WARRANTY: Bisco, Inc. recognizes its responsibility
to replace products if proven to be defective. Bisco,
Inc. does not accept liability for any damages or loss,
either direct or consequential, stemming from the use
of or inability to use the products described. Before
using, it is the responsibility of the user to determine
the suitability of the product for its intended use. The
user assumes all risk and liability in connection therewith.
Caution: U.S. Federal law restricts this device to sale
by or on the order of a dental professional.
Bisco, Inc.
1100 W. Irving Park Rd.
Schaumburg, IL 60193
1-(800)-BIS-DENT
847-534-6000
CE ADMINISTRATOR
Bisico France -
Mr. Fred Picavet
L'Opera- BP. 60
13680 Lancon De Provence
France
Phone: 33-490-42-9292
Fax: 33-490-42-9261
Rev. 7/97
IN-019
|
|
|