BISCO PIT AND FISSURE SEALANT
Light-Cured
|
|
BISCO PIT and FISSURE SEALANT is a light cured, filled, radiopaque,
white sealant designed to seal the pits and fissures of caries
susceptible teeth. |
DIRECTIONS FOR USE |
1. Clean the surfaces of the teeth to be sealed with prophy
paste or pumice. Rinse thoroughly. Isolate the teeth to be sealed
with a rubber dam or cotton rolls.
2. Place a small amount of ETCH-37™ (37% H3PO4) on the surface
of the tooth using the disposable angled syringe tip and manipulate
the etchant into the pits and fissures.
3. Allow the etchant to remain on the tooth for 15 seconds.
Thoroughly rinse the etchant with a generous water spray. Remove
pooled water with an oil-free stream of compressed air. Isolation
of the etched surface is paramount to the success of the procedure.
4. SHAKE SEALANT BOTTLE WELL BEFORE DISPENSING. The disposable
black dispenser tips can be placed directly on the sealant bottle
to dispense SEALANT, or use the supplied brushes. Place a thin
layer of sealant on the etched areas of the tooth.
5. Cure the sealant for at least 20 seconds on each surface.
For thicker or larger applications, longer exposures are desirable.
6. Check the applied sealant both visually and with an explorer.
If any part of the sealant can be dislodged by the explorer,
contamination of the etched surface has occurred. Remove the
dislodged sealant and repeat the entire procedure beginning
with step 1 above.
7. Check occlusion after the sealant has been cured and adjust
for any premature contact.
STORAGE: Store at room temperature (22°C/72°F). See individual
component labels for specific expiration dates.
CAUTIONS: ETCH-37 contains phosphoric acid. Avoid splashing
into the eyes. If etchants come in contact with the eyes, flush
with copious amounts of water and seek medical attention. Unpolymerized
resins may cause skin sensitization in susceptible persons.
In case of contact with the skin, wash thoroughly with soap
and water.
WARRANTY: Bisco, Inc. recognizes its responsibility to replace
products if proven to be defective. Bisco, Inc. does not accept
liability for any damages or loss, either direct or consequential,
stemming from the use of or inability to use the products described.
Before using, it is the responsibility of the user to determine
the suitability of the product for its intended use. The user
assumes all risk and liability in connection therewith.
Caution: U.S. Federal law restricts this device to sale by or
on the order of a dental professional.